DOC-ID: LUX-04REV: BDATE: 2026-07-21

Common Lantern Lighting

Residential lighting specs for Malmö homes

01 — Scope

LUX-04 defines dimming protocols, scene presets, and control hardware requirements for residential lighting in Malmö. All layers (LUX-01 through LUX-03) must be circuited to allow independent dimming unless explicitly grouped in a named scene.

02 — Dimming Parameters

ParameterValueNotes
Dimming protocolTrailing-edge phase dim or 0–10 VMatch driver specification per LUX-05
Minimum level (ambient)1–5%No visible flicker at minimum
Minimum level (task)10%Higher floor for visual task comfort
Fade time — scene change2–4 sEntry and evening transitions
Fade time — manual adjustImmediate to 1 sUser expectation at wall switch
Curve typeLogarithmic (perceptual linear)Document curve ID in handoff schedule

03 — Scene Presets

Scene IDAmbient (LUX-01)Task (LUX-02)Entry (LUX-03)Notes
S-01 DAYOff or 20%100% kitchenOffDaylight-dominant; task only where needed
S-02 EVENING60%80% kitchen, off desk50%Default return-home scene
S-03 DINING30%OffOffPendant at 70% if separate circuit
S-04 NIGHT5%OffPIR onlyPath lighting for bathroom trips
S-05 AWAYOffOffRandomised PIRSecurity simulation — optional module

04 — Control Hardware

ParameterValueNotes
Wall switch minimum1-gang dimmer per zonePush-on/off, rotate dim preferred
Multi-scene controlKeypad (4–6 scene) at entryLabelled with scene IDs above
Smart integrationOptional — not requiredIf specified, document API and local-fail behaviour
BRF restrictionsCheck styrordningSome Malmö BRFs restrict wireless mesh in common walls

05 — Prose — Commissioning

Dimming curves must be commissioned on-site after all finishes are installed. Plaster, paint, and floor reflectance alter perceived brightness by 15–25%. A commissioning visit includes scene verification, minimum-level flicker check, and handoff of a printed scene schedule to the electrician and homeowner.

Commissioning is included in packages above 35 000 SEK. Standalone commissioning visit: 2 800 SEK within Malmö.